CAS Num: 000589-98-0

SMILES : OC(CCCCC)CC

CHEM : 3-Octanol

MOL FOR: C8 H18 O1

MOL WT : 130.23

------------------------------ EPI SUMMARY (v4.00) --------------------------

Physical Property Inputs:

Water Solubility (mg/L): ------

Vapor Pressure (mm Hg) : ------

Henry LC (atm-m3/mole) : ------

Log Kow (octanol-water): ------

Boiling Point (deg C) : ------

Melting Point (deg C) : ------

Log Octanol-Water Partition Coef (SRC):

Log Kow (KOWWIN v1.67 estimate) = 2.73

Boiling Pt, Melting Pt, Vapor Pressure Estimations (MPBPWIN v1.43):

Boiling Pt (deg C): 181.87 (Adapted Stein & Brown method)

Melting Pt (deg C): -27.45 (Mean or Weighted MP)

VP(mm Hg,25 deg C): 0.0996 (Mean VP of Antoine & Grain methods)

VP (Pa, 25 deg C) : 13.3 (Mean VP of Antoine & Grain methods)

MP (exp database): -16 deg C

BP (exp database): 195 deg C

VP (exp database): 2.56E-01 mm Hg (3.41E+001 Pa) at 25 deg C

Water Solubility Estimate from Log Kow (WSKOW v1.41):

Water Solubility at 25 deg C (mg/L): 1379

log Kow used: 2.73 (estimated)

no-melting pt equation used

Water Sol (Exper. database match) = 1250 mg/L (25 deg C)

Exper. Ref: BEILSTEIN

Water Sol (Exper. database match) = 586 mg/L (25 deg C)

Exper. Ref: HANSCH,C ET AL. (1968)

Water Sol Estimate from Fragments:

Wat Sol (v1.01 est) = 1285.3 mg/L

ECOSAR Class Program (ECOSAR v1.00):

Class(es) found:

Neutral Organics

Henrys Law Constant (25 deg C) [HENRYWIN v3.20]:

Bond Method : 3.10E-005 atm-m3/mole (3.14E+000 Pa-m3/mole)

Group Method: 6.43E-005 atm-m3/mole (6.52E+000 Pa-m3/mole)

For Henry LC Comparison Purposes:

User-Entered Henry LC: not entered

Henrys LC [via VP/WSol estimate using User-Entered or Estimated values]:

HLC: 1.238E-005 atm-m3/mole (1.254E+000 Pa-m3/mole)

VP: 0.0996 mm Hg (source: MPBPVP)

WS: 1.38E+003 mg/L (source: WSKOWWIN)

Log Octanol-Air Partition Coefficient (25 deg C) [KOAWIN v1.10]:

Log Kow used: 2.73 (KowWin est)

Log Kaw used: -2.897 (HenryWin est)

Log Koa (KOAWIN v1.10 estimate): 5.627

Log Koa (experimental database): None

Probability of Rapid Biodegradation (BIOWIN v4.10):

Biowin1 (Linear Model) : 0.9527

Biowin2 (Non-Linear Model) : 0.9840

Expert Survey Biodegradation Results:

Biowin3 (Ultimate Survey Model): 3.3697 (days-weeks )

Biowin4 (Primary Survey Model) : 4.0584 (days )

MITI Biodegradation Probability:

Biowin5 (MITI Linear Model) : 0.6831

Biowin6 (MITI Non-Linear Model): 0.8649

Anaerobic Biodegradation Probability:

Biowin7 (Anaerobic Linear Model): 0.4561

Ready Biodegradability Prediction: YES

Hydrocarbon Biodegradation (BioHCwin v1.01):

Structure incompatible with current estimation method!

Sorption to aerosols (25 Dec C)[AEROWIN v1.00]:

Vapor pressure (liquid/subcooled): 34.1 Pa (0.256 mm Hg)

Log Koa (Koawin est ): 5.627

Kp (particle/gas partition coef. (m3/ug)):

Mackay model : 8.79E-008

Octanol/air (Koa) model: 1.04E-007

Fraction sorbed to airborne particulates (phi):

Junge-Pankow model : 3.17E-006

Mackay model : 7.03E-006

Octanol/air (Koa) model: 8.32E-006

Atmospheric Oxidation (25 deg C) [AopWin v1.92]:

Hydroxyl Radicals Reaction:

OVERALL OH Rate Constant = 17.2839 E-12 cm3/molecule-sec

Half-Life = 0.619 Days (12-hr day; 1.5E6 OH/cm3)

Half-Life = 7.426 Hrs

Ozone Reaction:

No Ozone Reaction Estimation

Fraction sorbed to airborne particulates (phi):

5.1E-006 (Junge-Pankow, Mackay avg)

8.32E-006 (Koa method)

Note: the sorbed fraction may be resistant to atmospheric oxidation

Soil Adsorption Coefficient (KOCWIN v2.00):

Koc : 33.7 L/kg (MCI method)

Log Koc: 1.528 (MCI method)

Koc : 105.6 L/kg (Kow method)

Log Koc: 2.024 (Kow method)

Aqueous Base/Acid-Catalyzed Hydrolysis (25 deg C) [HYDROWIN v2.00]:

Rate constants can NOT be estimated for this structure!

Bioaccumulation Estimates (BCFBAF v3.00):

Log BCF from regression-based method = 1.470 (BCF = 29.48 L/kg wet-wt)

Log Biotransformation Half-life (HL) = -0.6389 days (HL = 0.2297 days)

Log BCF Arnot-Gobas method (upper trophic) = 1.543 (BCF = 34.88)

Log BAF Arnot-Gobas method (upper trophic) = 1.543 (BAF = 34.88)

log Kow used: 2.73 (estimated)

Volatilization from Water:

Henry LC: 3.1E-005 atm-m3/mole (estimated by Bond SAR Method)

Half-Life from Model River: 22.72 hours

Half-Life from Model Lake : 343.5 hours (14.31 days)

Removal In Wastewater Treatment:

Total removal: 5.54 percent

Total biodegradation: 0.11 percent

Total sludge adsorption: 3.80 percent

Total to Air: 1.63 percent

(using 10000 hr Bio P,A,S)

Level III Fugacity Model:

Mass Amount Half-Life Emissions

(percent) (hr) (kg/hr)

Air 2.66 14.9 1000

Water 32.3 208 1000

Soil 65 416 1000

Sediment 0.0951 1.87e+003 0

Persistence Time: 251 hr

Top of Page Home